CyberScan DO 600
是 Eutech Instruments 溶解氧测量仪,原始说明为:Wide Measurement Range - Measures oxygen concentration up to 90.00mg/L and Saturation up to 600.0% – one of the widest measurement range in the...
广西科米瑞实验仪器设备有限公司提供 Eutech Instruments CyberScan DO 600 产品资料、选型咨询、供货报价和售后服务支持,价格面议。
← 返回产品列表
Wide Measurement Range - Measures oxygen concentration up to 90.00mg/L and Saturation up to 600.0% – one of the widest measurement range in the DO handheld market today!
Large Data Storage - Mega-storage space saves up to 500 data sets stamped with time and date – Perfect for GLP-compliant researches
Comprehensive Compensation - Salinity, temperature and pressure compensation – accurate even under varying conditions
Intelligent Display - Comprehensive one-glance-tells-all screen with intelligent screen prompts
Calibration Reminder - Cal-due alarm on real-time clock ensures periodic calibration updates
Waterproof Design - IP67 waterproof design for applications in harsh environments
Auto-logging - Automatically records up to 500 data sets stamped with date and time–Great for GLP-compliant researches
Data Communication - LED-RS232 and IrDA Wireless Communication for direct Meter-to-PC data transfer
Easy Calibration - Convenient 2-point calibration with step-by-step calibration guide
Instant Measurements - Galvanic, so you don’t have to wait for meter to warm up
Routine Testing: For quick, accurate dissolved oxygen checks in laboratories, field and schools. Useful in aquaculture and aquariums.
Industrial: Biological Wastewater Treatment; Fermentation
Water Quality Testing: Environmental monitoring
| 型号/系列 | CyberScan DO 600 |
|---|---|
| Dissolved Oxygen | Range: 0.00 to 90.00 mg/L or ppm Resolution: 0.01 mg/L or ppm Accuracy: ±0.2 mg/L |
| % Saturation | Range: 0.0 to 600.0% Resolution: 0.1% Accuracy: ±2 % |
| Temperature | Range: 0.0 to 50.0 °C (32 to 122 °F) Resolution: 0.1 °C (0.1 °F) Accuracy: ±0.3 °C (±0.5 °F) Compensation: ATC / MTC (0.0 to 50 °C) |
| Salinity Correction | Range: 0.0 to 50.0 ppt Resolution: 0.1 ppt Method: Automatic correction after manual input |
| Pressure Correction | Range: 450 to 825mmHg (59.9 to 109.9 kPa) Resolution: 1 mmHg (0.1 kPa) Method: Automatic correction with inbuilt sensor |
| Calibration | 2 Point (0%, 100%) |
| Operating Range |
请填写必填信息,我们将在工作日尽快回复。
| 0.0 to 50.0 °C (32 to 122 °F) |
| Probe Type | Galvanic |
|---|
| Date/Time Stamping | Yes |
|---|
| Memory | 500 data sets (GLP-compliant format) |
|---|
| Special Functions | Auto-Hold; Auto Power-Off after 2 - 30 minutes (user-preset); Stability Indicator; Self-diagnostics messages |
|---|
| 功率 | 4 x 1.5 ‘AA’ batteries (>400 hours) or 9V DC adapter, 500 mA |
|---|