Thermo Scientific Alpha COND 1000

Thermo Scientific Alpha COND 1000

是 Eutech Instruments 电导率测量仪,原始说明为:The Alpha COND 1000 features up to ten selectable conductivity ranges and corresponding cell constant K values, easily configured through a six...

品牌: Eutech Instruments价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司提供 Eutech Instruments Thermo Scientific Alpha COND 1000 产品资料、选型咨询、供货报价和售后服务支持,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
Thermo Scientific Alpha COND 1000
说明规格FAQ

说明

The Alpha COND 1000 features up to ten selectable conductivity ranges and corresponding cell constant K values, easily configured through a six-button keypad. Adjustable temperature co-efficient and ultrapure water compensation option allow measurements in broad-range applications, from ultrapure water to high-conductivity samples.

High Accuracy - ±1% full scale accuracy across ten different Conductivity ranges

Temperature Compensation - Adjustable temperature coefficient from 0.0 to 10.0% for higher accuracy

Pure Water Optimization - Pure water compensation option corrects non-linearity of pure water temperature correction curves in ultrapure water applications

Flexible Temperature Control - Option of Auto or Manual Temperature Compensation. Three-wire system compensates for cable-length resistance errors

Calibration Memory - Meter displays electrode information after each successful calibration. Previous calibration data is retained in the event of unsuccessful calibrations

Line Adjustment - Feature corrects long cable resistance errors – an important feature useful in applications involving high conductivity measurements

Quality Output - Galvanically-isolated, scaleable 0/4 to 20 mA output for high-quality output on peripheral devices

Use for virtually any batch or online applications where rapid, accurate control. Great for OEM/system integrator.

Use in applications involving agriculture, chemical processing, boiler and water heaters, wafer-fab, microprocessor manufacturing, pharmaceuticals, pulp and paper industries, and bleach manufacturing.

Use to treat batches of incoming process water, ultrapure water, boiler and feed water control.

Hook up to recorder for regulatory compliance data collection.

规格

型号/系列Thermo Scientific Alpha COND 1000
Range… to 1.999 µS/cm ; … to 19.99 µS/cm ; … to 199.9 µS/cm ; … to 1999 µS/cm ; … to 5000 µS/cm ; … to 19.99 mS/cm ; … to 199.9 mS/cm
Resolution0.001 µS/cm ; 0.01 µS/cm ; 0.1 µS/cm ; 1 µS/cm ; 5 µS/cm ; 0.01 mS/cm ; 0.1 mS/cm
Accuracy±1 % full scale reading
Cell Constant0.01 ; 0.1 ; 1 ; 10
Range-9.9 to 125 °C

提交需求

请填写必填信息,我们将在工作日尽快回复。

Resolution0.1 °C
Accuracy±0.5 °C
SensorPt100 / Pt1000 (jumper selectable)
CompensationAuto/manual (normalized at 25 °C)
CoefficientUltrapure water or linear 0.00 to 10.00 %
Set Point 1 (SP1) / Set Point 2 (SP2)… to 1.999 µS/cm or … to 19.99 µS/cm or … to 199.9 µS/cm or … to 5000 µS/cm or … to 19.99 mS/cm or … to 199.9 mS/cm
Switching Conductivity Hysteresis0 to 10 % of full scale
Function (Switchable)P control (pulse length/pulse frequency); limit control
Adjustable Period With Pulse Length Controller0.5 to 20 sec
Adjustable Period With Pulse Frequency Controller60 to 120 pulse/min
Pickup/Dropout Delay0 to 2000 sec
Contact Outputs3 SPDT relays
Switching Voltage/Current/PowerMax. 250 VAC / max. 3 A / max. 600 VA
Function (Switchable)Steady or fleet (pulse)
Wash Cycle0.1 to 199.9 hr
Wash Duration1 to 1999 sec
Pickup Delay0 to 2000 sec
Switching Voltage/Current/PowerMax. 250 VAC / max. 3 A / max. 600 VA
Transmitter Function0/4 to 20 mA scalable outputs for Conductivity, galvanically isolated