Partica

Partica

规格参数。Model LA-1000 series / LA-970 series Measurement principle DIA / Dynamic imaging analysis / - LD Mie scattering and fraunhofer diffraction Total measurement range 0.01

品牌: HORIBA产地: Japan交期: 按配置沟通价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司生产销售 HORIBA Partica,可提供产品参数、报价和售后服务咨询,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
Partica

产品说明

Partica

规格参数

ModelLA-1000 series / LA-970 series
Measurement principleDIA / Dynamic imaging analysis / -
LDMie scattering and fraunhofer diffraction
Total measurement range0.01 - 8000 μm / 0.01 - 5000 μm
Measurement range (Wet)DIA / 0.3 - 3000 μm* / -
LD0.01 - 3000 μm
Measurement range (Dry)DIA / 1.1 - 8000 μm* / -
LD0.1 - 5000 μm
Light sourcesLD (650 nm): 5 mW, LED (405 nm): Maximum 10 mW
Number of cameras2 (Dual camera system) / -
Camera performanceMaximum 300 fps / -
Digital resolutionMinimum 0.3 μm / -
Measurement parametersMore than 30 image analysis parameters / -
Dimensions and weight **720 mm (W) x 565 mm (D) x 470 mm (H), Approximately 56 kg
Optional accessoriesPowderjet Dry Powder Feeder, MiniFlow unit, Fraction cell, High Concentration cell, Paste cell
MiniFlow (Circulation system)Small-volume circulation with organic solvents. Measurement needs as little as 35 mL of solvent (180 mL with conventional circulation systems).Dispersion is possible with the built-in ultrasonic probe.
Dry Powder FeederThe Dry Powder Feeder Unit can measure samples in a powder state. It supports both non-dispersed measurement by free fall and forced-dispersion measurement using compressed air.
High Concentration Cell*The High Concentration Cell is able to measure close to original concentration with low dilution or without dilution. Measure Inks, paints, pigments, emulsions without dilution.Positive and negative electrode materials of secondary batteries, etc.Observe changes in the agglomeration state based on concentration, etc.Agglomerated was found when a battery was measured near to original concentration.
Paste Cell*The Paste Cell can measure undiluted samples or samples dispersed in a viscous medium. Microparticles dispersed in high-viscosity samples or polymers.Magnetic powder: Measure magnetic powder by dispersing it in viscous oil to prevent re-agglomeration.
Fraction CellThe Fraction Cell can take measurement with samples as small as only 5 mL, minimize the amount of dispersant. The Fraction Cell is ideal when the sample is extremely small or you need to recover the entire sample. Measurement range: 0.01-1000 µm, suits organic solvents Cell volumes: 5 mL, 10 mL, 15 mLRare sampleMeasurements with highly volatile solvent

相关产品

EFT-60

Eft-60 NMR Spectrometers

EFT-60

Eft-90 NMR Spectrometers

Eft-90 NMR Spectrometers

EFT-90

SC-1

SC-1 Robotic Sample Changer

SC-1

PHERAstar FSX

PHERAstar FSX

PHERAstar FSX

CLARIOstar Plus

CLARIOstar Plus

CLARIOstar Plus

VANTAstar

VANTAstar

VANTAstar

提交需求

请填写必填信息,我们将在工作日尽快回复。