SLIA-300

SLIA-300

满足以 0.01µg/L (0.01 ppb) 的较高灵敏度测量超低密度二氧化硅的客户需求。规格参数 Model Measurement method Molybdic blue absorptiometry Measurement range 0 to 2 / 0 to 20 µg/L, or 0 to 5 / 0 to 50 µg/L (pleas

品牌: HORIBA产地: Japan交期: 按配置沟通价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司生产销售 HORIBA SLIA-300,可提供产品参数、报价和售后服务咨询,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
SLIA-300

产品说明

满足以 0.01µg/L (0.01 ppb) 的较高灵敏度测量超低密度二氧化硅的客户需求

规格参数

ModelSLIA-300
Measurement methodMolybdic blue absorptiometry
Measurement range0 to 2 / 0 to 20 µg/L, or 0 to 5 / 0 to 50 µg/L (please specify when placing an order)
Measurement time5 minutes
Measurement points1 to 6 points (please specify when placing an order)
Reproducibility±2% of full scale
Calibration functionStandard fluid calibration
Compensation functionBlank compensation Metage line compensation (Specific to each line)
Reagent used· Reagent A: sulfuric acid + ammonium molybdate · Reagent B: oxalic acid · Reagent C: L (+) - ascorbic acid
Reagent replacement intervalOne week (according to the recommended period of our company)
Power100 to 240 V AC 50/60 Hz
Max. power consumptionApprox. 600 VA
Installation conditionIndoor, Ambient temperature 10 to 35°C, Humidity 85% or lower
Sample water condition· Water temperature: 15 to 35°C · Supplied flow rate: 250 to 300 mL/min (must be adjustable) · Pressure: 0.1 to 0.5 MPa
Outside dimensions580 (W) x 375 (H) x 500 (D) mm
WeightOne-point measurement: approx. 41 kg (plus 1 kg for an additional measurement point)
External I/ODensity output / 4 to 20 mA DC / 0 to 16 mA DC / 0 to 1 V DC (to be specified at order)
Contact output· Common to all lines: During measurement, synchronous signals, alarms (batch), heaters, power off, calibration signals 1 and 2, density upper limit warning, or sample water off. · Specific to each line: Measurement range, density upper limit warning, or sample water off (the density limit warning or the sample water off batch or respective line alarm should be specified when placing an order. The alarm contents should be also selected when placing the order.)
Contact input· Common to all lines:Calibration start, measurement start, cost-efficient operation, line selection, measurement low range, measurement high range
Serial I/ORS-232C
Applicable standardCE mark, FCC Part 15
OptionSample water heating unit, standard fluid supply unit, reagent blending tools

相关产品

EFT-60

Eft-60 NMR Spectrometers

EFT-60

Eft-90 NMR Spectrometers

Eft-90 NMR Spectrometers

EFT-90

SC-1

SC-1 Robotic Sample Changer

SC-1

PHERAstar FSX

PHERAstar FSX

PHERAstar FSX

CLARIOstar Plus

CLARIOstar Plus

CLARIOstar Plus

VANTAstar

VANTAstar

VANTAstar

提交需求

请填写必填信息,我们将在工作日尽快回复。