VS70-PDA-HDR

规格参数。Spectral Coverage UV-VIS (200–800 nm) with 477 l/mm grating, VIS (280--700 nm) with 582 l/mm grating, UV-NIR (200–985 nm) with double blazed 365 l/mm grating. On reques

品牌: HORIBA产地: Japan交期: 按配置沟通价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司生产销售 HORIBA VS70-PDA-HDR,可提供产品参数、报价和售后服务咨询,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
VS70-PDA-HDR

产品说明

VS70-PDA-HDR

规格参数

Spectral CoverageUV-VIS (200–800 nm) with 477 l/mm grating, VIS (280--700 nm) with 582 l/mm grating, UV-NIR (200–985 nm) with double blazed 365 l/mm grating. On request, other spectral ranges available; different mechanical integration might be needed
Spectrometer InputFiber-coupled: FC or SMA; Free space: 12-25-37-50-62-75-100-125-150-200 μm slits; Other options available upon request
Spectral Resolution2 nm for 365 l/mm grating, 1 nm for 477 l/mm grating, 0.8 nm for 582 l/mm grating (25 μm slit for all)
Average Spectral Dispersion30.9 nm/mm for 365 l/mm grating, 23.7 nm/mm for 477 l/mm grating 16.3 nm/mm for 582 l/mm grating
Average Digital Resolution with 25 (50) μm pixel width0.8 (1.5) nm/px for 365 l/mm grating, 0.59 (1.2) nm/px for 477 l/mm grating, 0.4 (0.8) nm/px for 582 l/mm grating
Focal Length70 mm
OptionsSelection of high grade sensors: Hamamatsu® S1590x and S1012x families (other PDA sensors available upon request); Input port: SMA, FC, free space, custom input (e.g., round-to-line fiber bundle)
F/#F/2.8
Stray Light Rejection Typical0.01% for UV-VIS configuration measured at 400 nm and 700 nm with a 550 nm (40 nm band) bandpass filter, 31 μm slit-width
Wavelength Accuracy0.2 nm
Software**LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration)
Detector ModelHamamatsu S10124-1024 o r S15909-1024 with high UV sensitivity.
Sensor Format1024 x 1 pixels
PDA Pixel Size25 μm x 2500 μm
PDA Active Area25.6 mm x 2.5 mm
PDA Spectral ResponseS15909-1024 has improved spectral response (NO FRINGES) compared to S10124-1024. (See figure below)
Sensor TemperatureUncooled
Full Well Capacity624 Me- for S15909-1024 and 468 Me- for S10124-1024
Readout Noise14,700 e- (typical) for S15909-1024. S10124-1024 not yet evaluated
Digitization18-bit
Dynamic Range (FW/RN)42,500:1 (typical) for S15909-1024. S10124-1024 not yet evaluated
Max SNR (√FW)24,980:1 (typical) for S15909-1024 and 21,600:1 (typical) for S10124-1024
Non-linearity (measured on each system)< 0.4% (corrected)
Dark Current (at 25C ambient)190,000 e-/pix/s (typical) for S15909-1024 and 625,000 e-/pixel/s (typical) for S10124-1024
CommunicationUSB 2.0 High-speed, (USB 3.0 customizable)
Environmental ConditionsOperating temperature 15° C to 40° C ambient Relative humidity <70% (non-condensing) Storage temperature -25° C to 45° C
Power Requirements5 VDC @ 0.13 A, USB-powered or Molex connector
Detector ModelHamamatsu S15908-512 or S10121-512 with high UV sensitivity.
Sensor Format512 x 1 pixels
PDA Pixel Size50 μm x 2500 μm

相关产品

EFT-60

Eft-60 NMR Spectrometers

EFT-60

Eft-90 NMR Spectrometers

Eft-90 NMR Spectrometers

EFT-90

SC-1

SC-1 Robotic Sample Changer

SC-1

PHERAstar FSX

PHERAstar FSX

PHERAstar FSX

CLARIOstar Plus

CLARIOstar Plus

CLARIOstar Plus

VANTAstar

VANTAstar

VANTAstar

提交需求

请填写必填信息,我们将在工作日尽快回复。