8' Logic Class II, Type A2 Biological Safety Cabinets
Logic Class II, Type A2 Biosafety Cabinets (BSCs) offer comprehensive personnel, product and environmental protection from hazardous particulates, including agents requiring BSL...
广西科米瑞实验仪器设备有限公司生产销售 Labconco 8' Logic Class II, Type A2 Biological Safety Cabinets,可提供产品参数、报价和售后服务咨询,价格面议。
← 返回产品列表
Logic Class II, Type A2 Biosafety Cabinets (BSCs) offer comprehensive personnel, product and environmental protection from hazardous particulates, including agents requiring BSL 1-4 containment. Ideal for applications involving antineoplastic drugs, genetic material and other hazardous airborne particulates. All models ensure the highest standard of safety and performance and are NSF/ANSI 49 compliant.
Designed for versatility, the Logic BSCs exhaust HEPA-filtered air into the laboratory, or into an exhaust system through the optional Ventus II Canopy Connection. When canopy-connected the Logic BSC can be used for applications involving minute quantities of volatile toxic chemicals and trace amounts of radionuclides.
Room air is drawn into the grille located in the air foil, and directed under the work surface by negative pressure. The air beneath the work surface contains unfiltered room air and air that has just passed through the work area. This air is drawn by the blower through the back plenum of the cabinet, where approximately 70% of the air is recirculated through the supply HEPA filter and back over the work area as laminar clean air. The balance of the contaminated air is discharged to the environment as clean air after passing through the exhaust HEPA filter.
Features (All Models)
Long-life DC Electronically Commutated Motor (ECM)
Constant Airflow Profile™ (CAP) airflow monitoring system
BalanceFlow™ plenum provides energy-efficiency and ultra-quiet operation*
Easy clean top cover that promotes even exhaust airflow from the top cover
Mag-Zone™ area on interior right side manages storage challenges with Labconco Magnetic Mag-Zone accessories
Intrinsically-safe negative pressure design
Fully scannable 99.99+% supply and exhaust HEPA filters. 99.999% efficient ULPA filters or H14 HEPA filters also available
Logic OS and 5" interior-mounted, line-of-sight touchscreen information center
Smart-Start™ System allows user to start up and shut down cabinet functions by raising and lowering the sash
Night-Smart™ System for idling the blower when the sash is fully closed
Full operational maintenance and certification logs for detailed record keeping
Status line for alarm conditions and alerts to warn when filter life diminishes to 20% and 10% before alarming at 0%
Interval/elapsed timer for experiment monitoring
UV light timer (on models with UV)
Password protection for cabinet settings
8 Languages
Bright, glare-free LED lighting up to 180 foot-candles (1937 lux). Located outside the contaminated work area
Curved, stainless steel inlet grille with waterfall design and Reserve-Air™ Secondary Airflow Slots
Air-Wave™ Entry System at access opening to enhance containment
Contain-Air™ Negative Pressure Channel at top of sash to enhance containment
Two electrical outlets. Flush mounted stainless steel cover with dampened hinges
115V GFCI, double receptacles, maximum amperage draw 5A
230V, single receptacles, maximum amperage draw 3A
10° angled, fully closing sash. 1/4" tempered safety glass with counterbalanced, anti-racking, easy-to-lift mechanism
Unitized, pressure tested stainless steel interior. Optic White epoxy-coated steel exterior
Removable towel catch located under work surface
8" or 10" (20.3 or 25.4) working sash height
22.5" (57 cm) max. sash opening & 27.0" (69 cm) viewing height
Removable, seamless type 304 stainless steel, dished work surface with lift out knobs
Nominal inflow velocity of 105 fpm (0.53 m/sec)
Nominal downflow velocity of 55 fpm (0.28 m/sec).
Approximately 70% air recirculation
Noise level <60 dB (4ft 10" model)
10' (3 m) power cord with plug
Six year warranty
8’ width
请填写必填信息,我们将在工作日尽快回复。