BAM-1020-Beta
BAM-1020-Beta 是 Met One Instruments 颗粒物监测/采样仪,原始说明为:MetOne-BAM-1020-Datasheet-v2.2-20260319
广西科米瑞实验仪器设备有限公司生产销售 Met One Instruments BAM-1020-Beta,可提供产品参数、报价和售后服务咨询,价格面议。
← 返回产品列表
MetOne-BAM-1020-Datasheet-v2.2-20260319
BAM 1020-9805 Operation Manual Rev G
Service Bulletin BAM 1020 Gen 2 vs Gen 3
BAM-1020 Manual Valve Flow Calibrations
Zero Test Template and Sample Rev D
BAM-1020 Span Membrane Cleaning Procedure
Service Bulletin 3236-5 Rev History
BAM-1020 Filter Pressure Drop Setting
GAST Pump Rebuild Guide 680828-9800 Rev A
MEDO Pump Rebuild Instructions 680839-9800 Rev A
BAM 1020 Beta Attenuation Mass Monitor
The BAM 1020 from Met One Instruments Powered by Acoem is a continuous particulate monitor which automatically measures and records airborne particulate concentration levels (in milligrams or micrograms per cubic meter) using the industry-proven principle of beta ray attenuation. Thousands of BAM-1020 units are currently deployed worldwide, making the unit one of the most prolific air monitoring platforms in the world.
The BAM 1020 from Met One Instruments Powered by Acoem was the first instrument to obtain U.S. EPA Federal Equivalent Method (FEM) designation for continuous PM 2.5 monitoring, in addition to its longstanding EPA designation for PM 10 monitoring. The BAM 1020 has also obtained the corresponding PM 2.5 and PM 10 certifications in the European Union. Two BAM 1020 units can also be operated together as an EPA designated PM 10 – 2.5 coarse method. Met One Instruments Powered by Acoem supplies complete sampling accessory kits for compliance with each designation.
At the beginning of each sample hour, a small 14 C (carbon-14) source emits a constant source of high-energy electrons (known as beta rays) through a spot of clean filter tape. These beta rays are detected and counted by a sensitive scintillation detector to determine a zero reading. The BAM 1020 then advances this spot of tape to the sample nozzle, where a vacuum pump pulls a measured and controlled amount of outside air through the filter tape, loading it with ambient dust. At the end of the sample hour, this dust spot is placed back between the beta source and the detector, thereby causing attenuation of the beta ray signal which is used to determine the mass of the particulate matter on the filter tape. This mass is used to calculate the volumetric concentration of particulate matter in the sampled ambient air.
All data files are accessible via an industry standard duplex RS-232 serial port using common terminal programs or Met One Instruments’ software such as Air Plus® or Comet®. The data is available in a variety of formats including daily reports, last record, all data, and new records since last download. Configuration files, error logs, and flow statistics are also available. Ethernet and USB data collection are standard.
U.S. EPA Equivalent Method for PM 10 , PM 2.5 , and PM 10-2.5 monitoring.