中文English
科米瑞
首页联系我们
  1. 首页
  2. 产品中心
  3. 产品详情
科米瑞

© Copyright 科米瑞 2026

产品中心产品目录应用领域知识中心常见问题联系我们隐私政策桂ICP备2020008265号-5
广西科米瑞实验仪器设备有限公司13422079856122816084@qq.com
分析检测仪器生命科学仪器显微成像与光学样品前处理温控加热与制冷真空泵阀与流体科米瑞仪器应用领域实验室仪器选型

催化剂分析仪 BELCAT II

催化剂分析仪 BELCAT II

Unlock state-of-the-art catalyst characterization with the BELCAT II. The performance of solid catalysts is shaped by specific surface properties, with factors like nature and d...

品牌: Microtrac价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司生产销售 Microtrac 催化剂分析仪 BELCAT II,可提供产品参数、报价和售后服务咨询,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
Microtrac催化剂分析仪 BELCAT II产品图片

Unlock state-of-the-art catalyst characterization with the BELCAT II. The performance of solid catalysts is shaped by specific surface properties, with factors like nature and distribution of active sites, acidity, basicity, redox behavior, electronic structure, and surface morphology all playing critical roles in determining catalytic activity, selectivity, and stability. The BELCAT II delivers precise analysis of metal dispersion rates, metal surface areas, and average particle size for supported precious metal catalysts, helping researchers enhance catalyst performance while reducing costs. In addition to providing measurements of specific surface areas (BET) and adsorption kinetics, the BELCAT II determines adsorption capacity through breakthrough curve analyses. These data are essential for the development of innovative adsorbent materials. As a comprehensive catalyst analyzer, it combines all functions in a single device, offering broad applicability and extensive customization to support diverse research and development objectives.

All-In-One, Fully Automatic and Multi-Purpose Analyzer Why BELCAT II

Discover the standout capabilities of the BELCAT II instrument. Below is a list of its key features, designed to provide comprehensive and reliable catalyst analysis while offering flexibility to suit diverse research and development requirements.

Multi-Purpose Gas Dosing Design The integrated multiline gas manifold allows simultaneous connection of up to eight different gases - including two corrosive types - which are internally distributed throughout the system. This smart design supports software-controlled blending, enabling precise generation of customized gas mixtures directly within the unit. These blends can be used during sample pretreatment, analysis, pulse loop operations, and automated calibration. By eliminating the need for premixed gases and minimizing external tubing, the system enhances workflow efficiency, reduces operating costs, and significantly lowers the risk of leakage.

Alternative devices (single-purpose)

5 gas lines: 1. He, 2. N 2 , 3. O 2 / He, 4. H 2 / Ar, 5. CO / He

5 gas lines: 1. H 2 , 2. CO, 3. NH 3 / He, 4. O 2 , 5. N 2 O

8 gas lines needed to prepare the same gas(-mixtures)

Superior Temperature Control Experience rapid heating and cooling with a compact split furnace designed for high performance. Heating rates reach up to 110 °C/min from 50 to 500 °C, or 80 °C/min from 50 to 1000 °C, with a maximum operating temperature of 1100 °C. Integrated fan-assisted cooling shortens turnaround times, reducing the temperature from 400 to 50 °C in just 30 minutes. This boosts sample throughput and minimizes downtime. For advanced subambient applications, the CATCryo II cryogenic option delivers exceptional cooling down to -120 °C. It sets new standards in thermal management, cooling from 800 to 30 °C in only 10 minutes – unlocking new possibilities in adsorption research, material characterization, and precision-controlled experiments.

Outstanding Safety Measures Features an auto-locking safety-door, overheat protection, automatic shutdown, integrated alarms, and optional gas detection for the highest level of operational safety. The supplied zeolite trap – to remove moisture during TPR experiments – eliminates the need for liquid nitrogen.

Triple Sample Cell Design State-of-the-art design ensures efficient gas preheating and maximizes throughput for demanding workflows. The cylindrical design of the tube enhances ease of handling and increases safety by being tension-free and less prone to breakage.

Modular Design With Upgrade Capability Future-ready design allows enables on-demand upgrades directly in the field. Its expandable architecture supports seamless integration of a vapor dosing unit, external gas mixing module, and a cryogenic option for enhanced adsorption studies and accelerated cooling.

Versatile Measurement Condition Settings Sequential measurement mode allows for seamless combination of thermochemical methods and catalyst testing steps in a single workflow.

Compact Instrument Design With Small Footprint Compact and efficient design (W 500 x D 500 mm) fits effortlessly into any laboratory.

Purpose-Built for Precision Dedicated instrument designed specifically for pulse chemisorption analysis and temperature programmed methods, featuring minimized dead volume for exceptional accuracy. Equipped with a temperature-controlled, high-performance thermal conductivity detector (TCD) and advanced circuitry, delivering an unmatched signal-to-noise ratio for the most sensitive measurements.

Pulse Chemisorption With Total Confidence With calibrated volume, dedicated pressure and temperature sensors - every dose exceeds expectations. Customized gas mixtures are delivered on demand by the integrated gas blending system, eliminating the need for additional injection loops and ensuring smooth, efficient workflows.

Consists of an air thermostat unit, bubbler, heater and condenser. The condenser eliminates excess vapor. Two-stage process ensures precise vapor dosing at stable concentrations.

Allows mixing of three or more gases. One unit can install up to six lines. Corrosive gases are supported.

Low temperature electric furnace / CATCryo II

By applying the liquid nitrogen spray, the sample temperature can be continuously controlled from -120 °C. The cooling performance is improved with the optimal internal structure, and the liquid nitrogen consumption is drastically reduced.

Systemized quadrupole mass spectrometer, BELMASS II can be connected with BELCAT II. Multiple components of gases can be measured at high quantitative accuracy while linked with the BELCAT II software. Ideal for demanding experiments, including catalytic reactions.

Functional materials can react with moisture and oxygen in air, resulting in structural changes while potentially generating corrosive gases. The new AIRGUARD solution – developed by Microtrac – allows safe handling of samples without air-contact.

Separation performance evaluation of mixed gas

For DAC, CCUS, and CCS applications, the system enables breakthrough curve measurements with multiple gaseous components such as CO2 and H2O that can be analyzed using dedicated highly stable and repeatable sensor detectors. Options: CO 2 probes CO 2 / H 2 O probes

NH 3 -TPD Measurement Result of Type MFI Zeolite

Desorption amount 0.835 mmol/g (2 = H peak value); Peak temperature 440 °C

Convenient conversion of time-based data into temperature-dependent profiles

Pt/Al 2 O 3 Metal Dispersion Rate by CO Pulses

Desorption amount: 0.527 cm³/g, Metal dispersion rate: 22.7%, Metal surface area 1.13 m²/g, Metal particle size: 4.99 nm.Fully automated base line correction and integration of pulses for effortless evaluation of data.

CO 2 Adsorption Breakthrough Curve Measurement

提交需求