Cole-Parmer® SamplePrep HG-800 Geno/Grinder® Automated Tissue Homogenizer and Cell Lyser
Integrates with automated robotic systems. The clamp mechanism is automatically secured before the grinding process begins. Accommodates all standard titer plates. Complete cycl...
广西科米瑞实验仪器设备有限公司提供 SPEX SamplePrep Cole-Parmer® SamplePrep HG-800 Geno/Grinder® Automated Tissue Homogenizer and Cell Lyser 产品资料、选型咨询、供货报价和售后服务支持,价格面议。
← 返回产品列表
Cole-Parmer® SamplePrep HG-800 Geno/Grinder® Automated Tissue Homogenizer and Cell Lyser Integrates with automated robotic systems. The clamp mechanism is automatically secured before the grinding process begins. Accommodates all standard titer plates. Complete cycle time is two minutes or less. Fast and efficient extraction of nucleic acids, proteins and other molecules. Average processing time of two minutes or less gives the unit the ability to run around the clock. The Cole-Parmer SamplePrep HG-800 GenoGrinder is designed to effectively disrupt cellular materials by oscillating one or two deep-well titer plates vertically. It is ideal for high-throughput processing of samples for isolation of nucleic acids (RNA/DNA), enzymes, yeast, proteins, and bacteria. It automates high-throughput homogenization by allowing users to run a large number of pre-loaded stacked titer plates unattended. The HG-800 accommodates titer plates, vials, and standard SPE plates for maximum versatility. The unit works with or without buffer using various grinding media. The Geno/Grinder seamlessly integrates with most robotic platforms, eliminating manual handling, and creating a fully automated workflow. A robotic arm places the titer plate(s) into the clamp, starts the run, and transfers the plates for the next step. Designed for fast and efficient sample processing, the HG-800 Geno/Grinder disrupts seeds, stems, roots, leaves, and animal tissue in two minutes or less. The vertical shaking motion provides powerful and consistent disruption, pulverizing dry samples with grinding balls for effective tissue breakdown. The Cole-Parmer SamplePrep HG-800 is customizable for your needs. It has adjustable stroke rate settings from 500 to 1750 stroked per minute, and run times from 15 seconds to 20 minutes, tailored to your specific application. The automatic clamp mechanism secures the plates before the grinding process begins for worry-free operation. The password-protected, touch screen control panel enables you to program run time, rate, cycles, and pause time. Up to 500 protocols can be easily labeled, saved, recalled, and exported via USB. Integrates with automated robotic systems. The clamp mechanism is automatically secured before the grinding process begins. Accommodates all standard titer plates. Complete cycle time is two minutes or less. Fast and efficient extraction of nucleic acids, proteins and other molecules. Average processing time of two minutes or less gives the unit the ability to run around the clock. The Cole-Parmer SamplePrep HG-800 GenoGrinder is designed to effectively disrupt cellular materials by oscillating one or two deep-well titer plates vertically. It is ideal for high-throughput processing of samples for isolation of nucleic acids (RNA/DNA), enzymes, yeast, proteins, and bacteria. It automates high-throughput homogenization by allowing users to run a large number of pre-loaded stacked titer plates unattended. The HG-800 accommodates titer plates, vials, and standard SPE plates for maximum versatility. The unit works with or without buffer using various grinding media. The Geno/Grinder seamlessly integrates with most robotic platforms, eliminating manual handling, and creating a fully automated workflow. A robotic arm places the titer plate(s) into the clamp, starts the run, and transfers the plates for the next step. Designed for fast and efficient sample processing, the HG-800 Geno/Grinder disrupts seeds, stems, roots, leaves, and animal tissue in two minutes or less. The vertical shaking motion provides powerful and consistent disruption, pulverizing dry samples with grinding balls for effective tissue breakdown. The Cole-Parmer SamplePrep HG-800 is customizable for your needs. It has adjustable stroke rate settings from 500 to 1750 stroked per minute, and run times from 15 seconds to 20 minutes, tailored to your specific application. The automatic clamp mechanism secures the plates before the grinding process begins for worry-free operation. The password-protected, touch screen control panel enables you to program run time, rate, cycles, and pause time. Up to 500 protocols can be easily labeled, saved, recalled, and exported via USB. Model Number HG-800 Type of Mill Automated, vertical impact grinder, designed for robotic systems and platforms Capacity One standard well titer plate (e.g. 96-well), or two standard well titer plates with optional dual clamp (sold separately) Display Touchscreen Grinding Mechanism Grinding balls of stainless steel, silica or zirconia beads Motor 3-phase servo Clamp Speed Adjustable range: 500-1750 strokes/minute Clamp Travel 3.2 cm (1.25 in.) Voltage 115 V/60 Hz or 230 V, 50 Hz Circuit Breaker (3) circuit breaker switches Power Cord 115 V/60 Hz model: 3-prong grounded plug supplied 230 V/50 Hz model: 2-prong European plug supplied Dimensions (H x W x D) 91.1 x 32.7 x 48.0 cm (35.9 x 12.9 x 18.9 in.) Net Weight 58 kg (125 lb) Operating Conditions For indoor use only at a maximum altitude of 2000 m (6600 ft). Operate at ambient conditions between 5 ºC and 40 ºC (40 °F and 104 ºF) with maximum relative humidity 80% below 31 ºC (88°F). Pollution degree 1: none or only dry, conductive pollution occurs. CE Approved Yes Automated, vertical impact grinder, designed for robotic systems and platforms One standard well titer plate (e.g. 96-well), or two standard well titer plates with optional dual clamp (sold separately) Grinding balls of stainless steel, silica or zirconia beads Adjustable range: 500-1750 strokes/minute 115 V/60 Hz model: 3-prong grounded plug supplied 230 V/50 Hz model: 2-prong European plug supplied 91.1 x 32.7 x 48.0 cm (35.9 x 12.9 x 18.9 in.) For indoor use only at a maximum altitude of 2000 m (6600 ft). Operate at ambient conditions between 5 ºC and 40 ºC (40 °F and 104 ºF) with maximum relative humidity 80% below 31 ºC (88°F). Pollution degree 1: none or only dry, conductive pollution occurs. HG-800 Geno/Grinder® Operation Manual
请填写必填信息,我们将在工作日尽快回复。
| 技术参数 | Cole-Parmer® SamplePrep HG-800 Geno/Grinder® Automated Tissue Homogenizer and Cell Lyser |
|---|---|
| Adjustable range | 500-1750 strokes/minute |
| 技术参数 | Dimensions (H x W x D) |