BLACK-Comet-SR Spectrometer
Measurements in the 200-1080nm or 220-1100nm range Concave grating optics for high performance applications
广西科米瑞实验仪器设备有限公司生产销售 StellarNet BLACK-Comet-SR Spectrometer,可提供产品参数、报价和售后服务咨询,价格面议。
← 返回产品列表
BLACK-Comet-SR Spectrometer Measurements in the 200-1080nm or 220-1100nm range Concave grating optics for high performance applications Super Range concave grating with dual blaze for best sensitivity Enhanced spectral imaging with no mirrors for lowest possible stray light Flat field imaging for uniform resolution No optical adjustments for extreme thermal stability TEC upgrade increases S/N by 60% Interchangeable Slit upgrade Options – Now available! Concave gratings white paper BLACK-Comet-SR Spectrometer Overview BLACK-Comet Optics- The concave holographic grating is aberration corrected and has no mirrors to minimize stray light with superb imaging projecting a flat field on the detector StellarNet BLACK-Comet-SR concave grating spectrometers deliver high performance spectral analysis in the UV-VIS-NIR wavelength range covering 200-1080nm (model C-SR) or 220-1100nm (model CXR-SR). Research Grade Optical Performance – The BLACK-Comet-SR UV-VIS-NIR spectrometers utilize a Dual Blaze 40mm diameter concave grating with aberration correction to provide the best optical performance of any compact spectrometer on the market. Improved spectral shapes by reducing coma and astigmatism found in plane grating spectrograph designs. Stray light reduction- The spectrograph architecture does not utilize mirrors, and therefore provides the lowest possible stray light, which is especially helpful for UV applications. Enhanced sensitivity- due to the spectrometers ability to reduce light scatter, especially high power UV light, the BLACK-Comet provides two to three times enhanced UV sensitivity as compared to plane grating/Czerny Turner optical configurations. Uniform resolution – The concave grating produces a flat field on the CCD detector creating uniform resolution over the entire spectral range. Thermal Stability- Optical bench architecture without mounting turrets and optical posts (typically in most USB spectrometers) decreases thermal expansion and contraction and increases overall system performance with temperature change Check out our Technical Note on Concave Grating Optics Dual blaze super range models provide wide wavelength ranges. Choose from the tables of standard models with various slit options for your choice of slit resolution. New and improved electronics with a high speed 16-bit digitizer allows for fast data acquisition and a signal to noise of 1000:1! Ruggedized – The detachable spectrograph assembly and control electronics are protected inside a rugged metal enclosure, suitable for portable, process, lab, and field applications. Interchangeable Slit Upgrade Options – Upgrade to your spectrometer’s optical bench input allows access to exchangeable slits. Includes pack of 14, 25 50, 100, 200um slits. 14um for best resolution and 200um for high sensitivity applications. New slit locking technology means no hardware or screwdriver is required creating the most flexible spectrometer solution on the planet. Multi-unit connection (up to 8) can be daisy chained together and are able to run simultaneously. USB Powered – BLACK-Comet-SR UV-VIS-NIR spectrometers can be powered directly from your PC’s USB-2 port. A single strand fiber optic cable or probe assembly delivers input via standard SMA 905 fiber optic connector with a choice of cable lengths. Onboard Memory with pre-set calibrations and spectrometer settings and snap shot memory to provide instantaneous spectral image from the highly sensitive CCD with 2048. High Speed Electronic Interface can be attached directly to a computers USB port for high speed data transfer. Options for Wifi/ethernet communication available as well as other interfaces. ContactUs@StellarNet.us for more info. BLACK-Comet-SR Technical Specifications Dynamic range: 2000:1 with 6 decades Optical resolution: < 1 nm Resolving Res. with 25um slit Detector type: CMOS/CCD or PDA, 2k/3k pixels Detector range: C-SR=200-1080nm or CXR-SR=220-1100nm Pixel size: 14 x 200um (CMOS/CCD) or 7 x 200um (PDA) Diffraction Gratings: Dual Blaze Concave; Aberration corrected Grating g/mm: Holographic, 590 g/mm Spectrograph: f/2, Flat field – No mirrors Order sorting filters: Integrated multi-band Signal to noise: 1000:1 CCD, *TEC optional upgrade Digitizer: 16-bit Dimensions: 69 x 100 x 150mm Power consumption: < 100 mA via USB port Interface Options: USB2 or Wifi (2), RS232 (3), SPI3, 4-20mA (3) Digital I/O (3) or ethernet (3) Detector Integration: 1ms to 8 minutes Data Transfer Speed: 30Hz or 1000Hz (1) Slit size options: 14, 25, 50, 100, 200um Stray light: 0.02% at 435 nm; 0.2% at 200 nm Fiber optic input: SMA-905 0.22na single fiber Operating systems: Windows and Linux (2), Andriod (2), iOS (2) Software included: SpectraWiz Program, WinSDK (C,C#,VB, Delphi), Customizable LabVIEW, VBA for Excel (CRI & LED Report) (1) zAP1 Electronics Upgrade (2) zAP2 Wifi + Applications Processor Upgrade with SpectraWiz Mobile Software (3) SMART-Control Interface BLACK-Comet-SR Technical Specifications < 1 nm Resolving Res. with 25um slit CMOS/CCD or PDA, 2k/3k pixels C-SR=200-1080nm or CXR-SR=220-1100nm 14 x 200um (CMOS/CCD) or 7 x 200um (PDA) Dual Blaze Concave; Aberration corrected f/2, Flat field – No mirrors
请填写必填信息,我们将在工作日尽快回复。