中文English
科米瑞
首页联系我们
  1. 首页
  2. 产品中心
  3. 产品详情
科米瑞

© Copyright 科米瑞 2026

产品中心产品目录应用领域知识中心常见问题联系我们隐私政策桂ICP备2020008265号-5
广西科米瑞实验仪器设备有限公司13422079856122816084@qq.com
分析检测仪器生命科学仪器显微成像与光学样品前处理温控加热与制冷真空泵阀与流体科米瑞仪器应用领域实验室仪器选型

Programmable Temperature Controller PTC10

PTC10

PTC10 Temperature Controller Introducing the PTC10 Programmable Temperature Controller—the ideal instrument for measuring temperature, controlling heaters, and logging temperatu...

品牌: Stanford Research Systems价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司提供 Stanford Research Systems PTC10 产品资料、选型咨询、供货报价和售后服务支持,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
Programmable Temperature Controller PTC10
说明规格FAQ

说明

PTC10 Temperature Controller Introducing the PTC10 Programmable Temperature Controller—the ideal instrument for measuring temperature, controlling heaters, and logging temperature data. The PTC10 Programmable Temperature Controller is a modular system that can be configured to suit a wide range of applications. The system consists of the PTC10 Controller and up to four I/O cards—two types of input cards for RTDs and thermocouples, and two types of output cards for driving heaters. ... click for PTC10 Tech Support 3D Step File PTC10 Volatility Statement CTC100 Temp. Contoller SIM921 AC Bridge SIM922 Diode Temp. Monitor SIM923 Pt RTD Temp. Monitor Cryo Temp. Contoller SIM921 AC Bridge SIM922 Diode Monitor SIM923 Pt RTD Monitor Introducing the PTC10 Programmable Temperature Controller from SRS—the ideal instrument for measuring temperature, controlling heaters, and logging temperature data. The PTC10 Programmable Temperature Controller is a modular system that can be configured to suit a wide range of applications. The system consists of the PTC10 Controller and up to four I/O cards—two types of input cards for RTDs and thermocouples, and two types of output cards for driving heaters. The I/O cards are ordered separately, and you can mix and match them in any way you wish. The PTC320 and PTC323 Thermistor/Diode/RTD readers can read a variety of resistive and diode temperature sensors. The PTC320 has a single input on a 6-pin circular DIN connector, while the PTC323 has two inputs on a 9-pin D-sub connector . The PTC321 RTD reader has four inputs for 100 Ω platinum RTD sensors. Each channel has a four-wire input with its own 1 mA current source for sensor excitation. The current can be reversed with each reading to cancel out stray thermocouple EMFs. The PTC330 four-channel thermocouple input card is factory configured to read either E, J, K, N or T type thermocouples. Each channel is electrically isolated allowing thermocouples to be attached to electrically-live equipment . An internal isothermal block, with its own RTD temperature sensor, provides highly accurate cold junction measurements. The PTC420 AC output card is a heater driver that switches up to 5 A of 100 VAC to 240 VAC line current with a solid-state relay . The output power is controlled by switching the current on for some fraction of a 10 s cycle period and off for the remainder of the period. The PTC420 is intended to drive large heaters with response times of more than about 10 s. A PTC chassis can run up to two PTC420s at full power simultaneously. The PTC430 and PTC431 DC output cards provide finer control for driving smaller, faster responding heaters. The PTC430 delivers up to 1 A of current at 50 VDC, while the PTC431 delivers up to 2 A at 50 VDC. The PTC440 TEC driver delivers ±5 A of current at ±12 VDC. This bipolar output card is optimized for driving thermoelectric coolers. It also includes a low resolution temperature sensor input that can read thermistors, RTDs, LM135, and AD590 sensors. For applications that require millikelvin resolution, a PTC320 card should be used with the PTC440. A PTC chassis can run up to three PTC430s and/or PTC440s at full power simultaneously. In a proportional-integral-differential (PID) feedback loop, the power supplied to a heater (the feedback output) is continually adjusted to keep a temperature reading (the input) at a predetermined value (the setpoint). The PTC10 offers up to six independent PID feedback outputs: one on each of up to two output cards, plus the four analog I/O channels. Any of the data channels can be used as the feedback input. PID feedback loops can be auto-tuned using either a single step response or a relay tuning method in which multiple steps create a temperature oscillation. Data Acquisition and Display All input channels are read simultaneously at rates between 1 Hz and the line frequency (50 or 60 Hz). Each input channel can be lowpass-filtered to reduce noise. Input channels can also be differenced with any other channel. Three “virtual channels”, which are not connected to any physical input, can display the results of more complex calculations. Standard calibration curves are included for popular sensor types. Custom calibration curves with up to 400 points each can also be applied to any input; the curves are stored on a removable USB memory device and are loaded by simply plugging the device into the PTC10. Sensor calibration can also be adjusted by entering an offset and gain from the front panel. The PTC10 has an internal data log that stores up to 1 million points per channel. Data can be written to the log at intervals between 0.1 s and 1 hr. The log rate can be set independently for each channel, or a global rate can be used. Data can also be logged to removable USB memory devices like flash keys, flash card readers, and USB hard drives. In this case, the maximum number of points that can be logged is determined by the size of the memory device. Input and output data can be displayed numerically or plotted on the LCD screen. Up to eight plots, each with up to eight data channels, can be displayed. You can zoom or pan the plots by touching or dragging your finger across the screen. Upper/lower alarm levels or rate-of-change limits can be assigned to each input. If these limits are exceeded, an audible alarm sounds, a specified relay trips, and a specified output channel can be shut off. Alarms can be latching or non-latching . Remote operation is supported with USB, GPIB (opt.), RS-232 , and Ethernet interfaces. All instrument functions can be controlled and read over any of the interfaces. When the USB interface is used, the PTC appears as a COM port on your PC. The PTC10 supports user-defined macros that consist of one or more remote commands. Macros can be controlled from the front panel, and up to ten macros can run simultaneously. Macros can call other macros, and conditional statements, variables, and loops are supported. Using the PTC10's three virtual channels, macro variables can be plotted on-screen, saved to logs, and/or used as inputs for feedback loops. Macros are a powerful tool that can be used to tailor the behavior of the PTC10 for your experiment. For example, infinite-loop macros running as background tasks can take steps to address alarm conditions, automatically switch between sensor inputs (or heater outputs) depending on the current temperature or other factors, or implement cascade feedback schemes. The PTC10 has four configurable general-purpose analog I/O channels, each of which can be used either as a 24-bit, ±10 V input or a 16-bit, ±10 V output. The PTC10 also has eight bidirectional digital I/O lines that can interact with macros, and four relays that can be tripped by alarms, remote commands, macros, or from the front panel. The PTC10’s analog I/O channels can be used as feedback inputs, and custom calibration curves can be applied to convert their voltage readings into temperature, pressure, e

相关产品

Synthesized Clock Generator - CG635

Synthesized Clock Generator - CG635

CG635

Synthesized Clock Generator - CG792

Synthesized Clock Generator - CG792

CG792

CIS - Closed Ion Source Gas Analyzers

CIS - Closed Ion Source Gas Analyzers

CIS

CS580 Current Source

CS580 Current Source

CS580

Cryogenic Temperature Controller - CTC100

Cryogenic Temperature Controller - CTC100

CTC100

Coax Delay Box - DB64

Coax Delay Box - DB64

DB64

提交需求

请填写必填信息,我们将在工作日尽快回复。

规格

技术参数Introducing the PTC10 Programmable Temperature Controller—the ideal instrument for measuring temperature, controlling heaters, and logging temperature data. The PTC10 Programmable Temperature Controller is a modular system that can be configured to s
技术参数The PTC10 Programmable Temperature Controller is a modular system that can be configured to suit a wide range of applications. The system consists of the PTC10 Controller and up to four I/O cards—two types of input cards for RTDs and thermocouples, a
技术参数The PTC320 and PTC323 Thermistor/Diode/RTD readers can read a variety of resistive and diode temperature sensors. The PTC320 has a single input on a 6-pin circular DIN connector, while the PTC323 has two inputs on a 9-pin D-sub connector .
技术参数The PTC321 RTD reader has four inputs for 100 Ω platinum RTD sensors. Each channel has a four-wire input with its own 1 mA current source for sensor excitation. The current can be reversed with each reading to cancel out stray thermocouple EMFs.
技术参数The PTC330 four-channel thermocouple input card is factory configured to read either E, J, K, N or T type thermocouples. Each channel is electrically isolated allowing thermocouples to be attached to electrically-live equipment . An internal isotherm
技术参数The PTC420 AC output card is a heater driver that switches up to 5 A of 100 VAC to 240 VAC line current with a solid-state relay . The output power is controlled by switching the current on for some fraction of a 10 s cycle period and off for the rem
技术参数The PTC430 and PTC431 DC output cards provide finer control for driving smaller, faster responding heaters. The PTC430 delivers up to 1 A of current at 50 VDC, while the PTC431 delivers up to 2 A at 50 VDC.
技术参数The PTC440 TEC driver delivers ±5 A of current at ±12 VDC. This bipolar output card is optimized for driving thermoelectric coolers. It also includes a low resolution temperature sensor input that can read thermistors, RTDs, LM135, and AD590 sensors.
技术参数In a proportional-integral-differential (PID) feedback loop, the power supplied to a heater (the feedback output) is continually adjusted to keep a temperature reading (the input) at a predetermined value (the setpoint). The PTC10 offers up to six in
技术参数Data Acquisition and Display
技术参数All input channels are read simultaneously at rates between 1 Hz and the line frequency (50 or 60 Hz). Each input channel can be lowpass-filtered to reduce noise. Input channels can also be differenced with any other channel. Three “virtual channels”
技术参数Standard calibration curves are included for popular sensor types. Custom calibration curves with up to 400 points each can also be applied to any input; the curves are stored on a removable USB memory device and are loaded by simply plugging the dev

FAQ