中文English
科米瑞
首页联系我们
  1. 首页
  2. 产品中心
  3. 产品详情
科米瑞

© Copyright 科米瑞 2026

产品中心产品目录应用领域知识中心常见问题联系我们隐私政策桂ICP备2020008265号-5
广西科米瑞实验仪器设备有限公司13422079856122816084@qq.com
分析检测仪器生命科学仪器显微成像与光学样品前处理温控加热与制冷真空泵阀与流体科米瑞仪器应用领域实验室仪器选型

SR200 - Gate Scanner

SR200

The SR200 Gate Scanner module is designed to automate waveform recovery with the SR250 and SR255 Gated Integrator modules. Waveform recovery is done by slowly scanning the gate ...

品牌: Stanford Research Systems价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司提供 Stanford Research Systems SR200 产品资料、选型咨询、供货报价和售后服务支持,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
SR200 - Gate Scanner
说明规格FAQ

说明

The SR200 Gate Scanner module is designed to automate waveform recovery with the SR250 and SR255 Gated Integrator modules. Waveform recovery is done by slowly scanning the gate of the integrator over the waveform of interest. Both the SR250 and SR255 modules have external gate delay control inputs. The SR200 provides an adjustable ramp voltage needed to scan the gates using these inputs. Signal Recovery with PMTs Boxcar Systems Scientific Instruments Signal Recovery — PMTs Boxcar Systems Sci. Instruments The SR200 Gate Scanner module is designed to automate waveform recovery with the SR250 and SR255 Gated Integrator modules. Waveform recovery is done by slowly scanning the gate of the integrator over the waveform of interest. Both the SR250 and SR255 modules have external gate delay control inputs. The SR200 provides an adjustable ramp voltage needed to scan the gates using these inputs. The initial and final delays, as well as the scan time, are fully adjustable. Single or repeated scans may be performed in the forward or reverse direction over any portion of the waveform. Scan times from 10 milliseconds to 5 minutes may be selected. In addition to the delay control output, the SR200 has a 0 to 10 volt X-axis ramp output designed to drive the X-axis of a chart recorder or an oscilloscope. SR200 Specifications Reverse/Stop/Forward Selects scan direction or stops scan Selects single/repeated scans or resets to start 10-turn pot sets the smallest delay multiplier (SR250) in the scan 10-turn pot sets the range of delays multiplier (SR250) in the scan Rear-panel output connects to the SR250/SR255 delay multiplier input. Impedance <1 Ω, 20 mA Logic signal to lift chart recorder pen or blank an oscilloscope trace Scans between 0 and 10 VDC regardless of start position and scan width setting +24 V/20 mA, +12 V/80 mA, -12 V/0 mA, -24 V/20 mA. 2 W Single-width NIM standard module One year parts and labor on defects in materials and workmanship

规格

技术参数The SR200 Gate Scanner module is designed to automate waveform recovery with the SR250 and SR255 Gated Integrator modules. Waveform recovery is done by slowly scanning the gate of the integrator over the waveform of interest. Both the SR250 and SR255
技术参数The SR200 Gate Scanner module is designed to automate waveform recovery with the SR250 and SR255 Gated Integrator modules. Waveform recovery is done by slowly scanning the gate of the integrator over the waveform of interest. Both the SR250 and SR255

相关产品

Synthesized Clock Generator - CG635

Synthesized Clock Generator - CG635

CG635

Synthesized Clock Generator - CG792

Synthesized Clock Generator - CG792

CG792

CIS - Closed Ion Source Gas Analyzers

CIS - Closed Ion Source Gas Analyzers

CIS

CS580 Current Source

CS580 Current Source

CS580

Cryogenic Temperature Controller - CTC100

Cryogenic Temperature Controller - CTC100

CTC100

Coax Delay Box - DB64

Coax Delay Box - DB64

DB64

提交需求

请填写必填信息,我们将在工作日尽快回复。

技术参数In addition to the delay control output, the SR200 has a 0 to 10 volt X-axis ramp output designed to drive the X-axis of a chart recorder or an oscilloscope.
技术参数10-turn pot sets the range of delays multiplier (SR250) in the scan
技术参数Rear-panel output connects to the SR250/SR255 delay multiplier input. Impedance <1 Ω, 20 mA

FAQ