中文English
科米瑞
首页联系我们
  1. 首页
  2. 产品中心
  3. 产品详情
科米瑞

© Copyright 科米瑞 2026

产品中心产品目录应用领域知识中心常见问题联系我们隐私政策桂ICP备2020008265号-5
广西科米瑞实验仪器设备有限公司13422079856122816084@qq.com
分析检测仪器生命科学仪器显微成像与光学样品前处理温控加热与制冷真空泵阀与流体科米瑞仪器应用领域实验室仪器选型

Frequency Counter - SR620

SR620

25 ps single-shot time resolution 1.3 GHz frequency range 11-digit frequency resolution (1 s) Statistical analysis & Allan variance Graphical output to XY scopes

品牌: Stanford Research Systems价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司提供 Stanford Research Systems SR620 产品资料、选型咨询、供货报价和售后服务支持,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
Frequency Counter - SR620
说明规格FAQ

说明

25 ps single-shot time resolution 1.3 GHz frequency range 11-digit frequency resolution (1 s) Statistical analysis & Allan variance Graphical output to XY scopes GPIB and RS-232 interfaces Ovenized timebase (opt.) 25 ps single-shot resolution 11-digit freq. resolution (1 s) Statistics & Allan variance SR620 Time Interval / Frequency Counter The SR620 Time Interval Counter performs virtually all of the time and frequency measurements required in a laboratory or ATE environment. The instrument's single-shot timing resolution and low jitter make it the counter of choice for almost any application. ... click for SR620 Tech Support Rack Mount Kit Drawing Front Panel Drawing Rear Panel Drawing SR620 Measurements Volatility Statement High-Res Measurements SR620 Error Terms Hyper Terminal Comm FS752 GPS/GNSS DO FS725 Rb Frequency Standard SR625 Rb Frequency Counter FS740 GPS Frequency Std. SG380 RF Signal Generator CG635 Clock Generator Rack Mount Kit Drawing Front Panel Drawing Rear Panel Drawing SR620 Measurements SR620 Volatility Statement High-Res Measurements SR620 Error Terms Hyper Terminal Comm FS752 GPS/GNSS DO FS725 Rb Freq. Std. SR625 Rb Freq. Counter FS740 GPS Freq. Std. SG380 RF Sig. Gen. CG635 Clock Gen. SR620 Frequency Counter Allan Variance Plot X Allan Variance Plot SR620 Frequency Counter The SR620 measures time interval, frequency, pulse-width, rise and fall time, period, phase and events. Time intervals are measured with 25 ps rms resolution, making the SR620 one of the highest resolution counters available. Frequency is measured from 0.001 Hz to 1.3 GHz, and a choice of gates ranging from 1 period to 500 seconds is provided. The SR620 delivers up to 11 digits of frequency resolution in one second, making it suitable for measurement applications ranging from short-term phase locked loop jitter, to the long-term drift of atomic clocks. All measurement modes are supported by a wide variety of flexible arming and triggering options. Histograms and Strip Charts Unlike conventional counters that only have numeric displays, the SR620 provides live, graphical displays of measurement results. Graphical data is available in three formats: a histogram showing the distribution of values within a set of measurements, a strip chart of mean values from successive measurements, or a strip-chart of jitter (standard deviation or Allan variance) values from successive measurements. Up to 250 strip-chart points , or histogram bins, can be displayed. Both histograms and strip charts can be displayed on any oscilloscope with an X-axis input (see pictures), or can be plotted on an HP-GL compatible plotter or dot-matrix printer . Convenient cursors allow you to read the value of any data point in the histogram or strip chart. Autoscale and zoom features make it simple to display all, or any portion, of the graphs. Histogram Display X Histogram Display SR620 Frequency Counter The SR620 can make measurements on a single-shot basis, or calculate the statistics of a set of measurements. Sample sizes from one to one million can be selected. The SR620 will automatically calculate the mean, standard deviation or Allan variance, minimum and maximum for each set of measurements. A precision 50 % duty cycle square wave (1 kHz) is available at the front-panel REF output. The REF output can be used as a source of start or stop pulses for any of the SR620's measurement modes. For instance, the length of a cable connected between REF and the B input can be precisely determined by measuring the time delay between REF and B. DVMs and Analog Outputs Two rear-panel DVM inputs make measurements of DC voltages with 0.3 % accuracy (±20 VDC range). These values may be read via the interfaces or displayed directly on the front panel. Two DAC outputs continuously provide voltages proportional to the mean and the jitter of the measurement sample. These 0 to 10 V outputs can drive strip chart recorders, or they can be set to provide fixed or scanned output voltages. Built-In Auto-Calibration A sophisticated, built-in auto-calibration routine nulls insertion delays between start and stop channels, and compensates for the differential nonlinearities inherent in analog time-measurement circuitry . The auto-calibration routine takes about two minutes to perform, and should be run every 1000 hours of operation. The choice of timebase affects both the resolution and accuracy of measurements made with the SR620. SRS offers a choice of a standard timebase with an aging coefficient of 1 × 10 -6 /year , or an optional ovenized-oscillator timebase with only 5 × 10 -10 /day aging, and about an order of magnitude better short-term stability than the standard timebase. A rear-panel input lets you connect any external 5 MHz or 10 MHz source as a timebase. Standard GPIB (IEEE-488.2) and RS-232 interfaces allow remote control of the SR620. All instrument functions and configuration menu settings are accessible via the interfaces. A fast binary dump mode outputs up to 1400 measurements per second to a computer. A parallel printer port allows direct printing from the instrument. Standard IEEE-488.2 communications are supported, and plotter outputs are provided in HP-GL format . For convenient debugging, the last 256 characters transmitted over the interfaces can be viewed on the front panel. SR620 Specifications Allan variance (1 s)

相关产品

Synthesized Clock Generator - CG635

Synthesized Clock Generator - CG635

CG635

Synthesized Clock Generator - CG792

Synthesized Clock Generator - CG792

CG792

CIS - Closed Ion Source Gas Analyzers

CIS - Closed Ion Source Gas Analyzers

CIS

CS580 Current Source

CS580 Current Source

CS580

Cryogenic Temperature Controller - CTC100

Cryogenic Temperature Controller - CTC100

CTC100

Coax Delay Box - DB64

Coax Delay Box - DB64

DB64

提交需求

请填写必填信息,我们将在工作日尽快回复。

规格

技术参数25 ps single-shot time resolution
技术参数1.3 GHz frequency range
技术参数11-digit frequency resolution (1 s)
技术参数Graphical output to XY scopes
技术参数GPIB and RS-232 interfaces
技术参数25 ps single-shot resolution
技术参数11-digit freq. resolution (1 s)
技术参数SR620 Time Interval / Frequency Counter
技术参数The SR620 Time Interval Counter performs virtually all of the time and frequency measurements required in a laboratory or ATE environment. The instrument's single-shot timing resolution and low jitter make it the counter of choice for almost any appl
技术参数FS752 GPS/GNSS DO FS725 Rb Frequency Standard SR625 Rb Frequency Counter FS740 GPS Frequency Std. SG380 RF Signal Generator CG635 Clock Generator
技术参数SR620 Frequency Counter
技术参数Allan Variance Plot X Allan Variance Plot SR620 Frequency Counter

FAQ