中文English
科米瑞
首页联系我们
  1. 首页
  2. 产品中心
  3. 产品详情
科米瑞

© Copyright 科米瑞 2026

产品中心产品目录应用领域知识中心常见问题联系我们隐私政策桂ICP备2020008265号-5
广西科米瑞实验仪器设备有限公司13422079856122816084@qq.com
分析检测仪器生命科学仪器显微成像与光学样品前处理温控加热与制冷真空泵阀与流体科米瑞仪器应用领域实验室仪器选型

Lock-In Amplifier High Frequency - SR844

SR844

SR844 Lock-In Amplifier The SR844 is the widest bandwidth lock-in amplifier available from SRS. It provides uncompromised performance with a frequency range of 25 kHz to 200 MHz...

品牌: Stanford Research Systems价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司提供 Stanford Research Systems SR844 产品资料、选型咨询、供货报价和售后服务支持,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
Lock-In Amplifier High Frequency - SR844
说明规格FAQ

说明

SR844 Lock-In Amplifier The SR844 is the widest bandwidth lock-in amplifier available from SRS. It provides uncompromised performance with a frequency range of 25 kHz to 200 MHz and up to 80 dB of drift-free dynamic reserve. The SR844 includes the many features, ease of operation, and programmability that you've come to expect from SRS DSP lock-in amplifiers . SR844 Tech Support Rack Mount Kit Drawing SR844 Volatility Statement SR865A Lock-In Amplifier SR830 Lock-In Amplifier SR860 Lock-In Amplifier SR445A Preamplifier SR446 Preamplifier SR844 Tech Support Rack Mount Kit Dwg. SR844 Volatility Statement SR865A Lock-In Amp. SR830 Lock-In Amp. SR860 Lock-In Amp. SR445A Preamp. SR446 Preamp. SR844 200 MHz Lock-In Amplifier SR844 RF Lock-In Amplifier The SR844 uses the same advanced DSP technology found in the SR850, SR830 and SR810 lock-in amplifiers . DSP offers many advantages over analog instruments—high dynamic reserve, low zero-drift, accurate RF phase shifts and orthogonality, and digital output filtering. The SR844 has both 50 Ω and 1 MΩ inputs. The 1 MΩ input is used with high source impedances at low frequencies, or with a standard 10× scope probe. The 50 Ω input provides the best RF signal matching. Full-scale sensitivities range from 1 Vrms (+13 dBm) down to 100 nVrms (-127 dBm). Up to 60 dB of RF attenuation or 20 dB of RF gain can be selected in 20 dB increments. Gain allocation can be optimized to provide up to 80 dB of dynamic reserve. The SR844 offers both external and internal reference operation. In both cases, the entire 25 kHz to 200 MHz frequency range is covered without any manual range selection. The external reference input has an auto-threshold feature which locks to sine, square or pulsed signals. The internal reference is digitally synthesized and is adjustable with 3-digit frequency resolution. Harmonic detection of the 2F component is available for both internal and external reference modes. A reference output (1.0 Vpp square wave into 50 Ω) which is phase synchronous with the lock-in reference is available in both external and internal mode. Time constants from 100 µs to 30 ks can be selected with a choice of 6, 12, 18 or 24 dB/oct rolloff. For high-bandwidth , real-time outputs, the filtering can be by-passed entirely . In this "No Filter" mode, the effective time constant is about 30 µs, with the analog outputs updating every 10 to 20 µs. The SR844 is easy to use. All instrument functions are set from the front-panel keypad, and the knob is used to quickly adjust parameters. Up to nine different instrument configurations can be stored in non-volatile memory for fast, reliable instrument setup. Standard RS-232 and GPIB (IEEE-488.2) interfaces provide connections to your data acquisition systems. Auto-functions allow parameters that are frequently adjusted to be set automatically. Sensitivity, dynamic reserve, phase and offset are each quickly optimized with a simple key stroke. The offset and expand features are useful for evaluating small fluctuations in your signal. The input is nulled with the auto-offset function, and output expand increases the resolution by up to 100×. Ratio mode is used to normalize the signal to an externally applied analog voltage. It is useful to eliminate the effect of source intensity fluctuations. Transfer function measurements can be easily made from the front panel by a programmable scan of up to 11 frequencies. Setups and offsets are recalled at each frequency in the scan. Analog Inputs and Outputs The two displays each have a user-defined output for measuring X, Y, R, R(dBm), Θ, and X-noise or Y-noise . Two user-programmable DACs provide -10.5 V to +10.5 V outputs with 1 mV resolution. These outputs may be set from the front panel or via the computer interfaces. In addition, there are two general purpose analog inputs. These are 16-bit ADCs which can be displayed on the front panel, read over the interface, or used to ratio the input signal. The SR844 has two 16,000 point memory buffers for recording the time history of each measurement display at rates up to 512 samples/s. Data may be transferred from the buffers using either interface. A trigger input is also provided to synchronize data recording with external events. Block Diagram X Block Diagram SR844 SR844 Specifications 50 Ω or 1 MΩ + 30 pF 100 nVrms to 1 Vrms full scale 1 µVrms to 1 Vrms full scale 10 µVrms to 1 Vrms full scale Low noise reserve, sensitivity <30 mV 2 nV/√Hz (typ.), 8 nV/√Hz (max.) 5 nV/√Hz (typ.), 8 nV/√Hz (max.) External reference input 50 Ω or 10 kΩ + 40 pF 0.7 Vpp pulse or 0 dBm sine

相关产品

Synthesized Clock Generator - CG635

Synthesized Clock Generator - CG635

CG635

Synthesized Clock Generator - CG792

Synthesized Clock Generator - CG792

CG792

CIS - Closed Ion Source Gas Analyzers

CIS - Closed Ion Source Gas Analyzers

CIS

CS580 Current Source

CS580 Current Source

CS580

Cryogenic Temperature Controller - CTC100

Cryogenic Temperature Controller - CTC100

CTC100

Coax Delay Box - DB64

Coax Delay Box - DB64

DB64

提交需求

请填写必填信息,我们将在工作日尽快回复。

规格

技术参数The SR844 is the widest bandwidth lock-in amplifier available from SRS. It provides uncompromised performance with a frequency range of 25 kHz to 200 MHz and up to 80 dB of drift-free dynamic reserve. The SR844 includes the many features, ease of ope
技术参数The SR844 uses the same advanced DSP technology found in the SR850, SR830 and SR810 lock-in amplifiers . DSP offers many advantages over analog instruments—high dynamic reserve, low zero-drift, accurate RF phase shifts and orthogonality, and digital
技术参数The SR844 has both 50 Ω and 1 MΩ inputs. The 1 MΩ input is used with high source impedances at low frequencies, or with a standard 10× scope probe. The 50 Ω input provides the best RF signal matching. Full-scale sensitivities range from 1 Vrms (+13 d
技术参数The SR844 offers both external and internal reference operation. In both cases, the entire 25 kHz to 200 MHz frequency range is covered without any manual range selection. The external reference input has an auto-threshold feature which locks to sine
技术参数A reference output (1.0 Vpp square wave into 50 Ω) which is phase synchronous with the lock-in reference is available in both external and internal mode.
技术参数Time constants from 100 µs to 30 ks can be selected with a choice of 6, 12, 18 or 24 dB/oct rolloff. For high-bandwidth , real-time outputs, the filtering can be by-passed entirely . In this "No Filter" mode, the effective time constant is about 30 µ
技术参数The SR844 is easy to use. All instrument functions are set from the front-panel keypad, and the knob is used to quickly adjust parameters. Up to nine different instrument configurations can be stored in non-volatile memory for fast, reliable instrume
技术参数The offset and expand features are useful for evaluating small fluctuations in your signal. The input is nulled with the auto-offset function, and output expand increases the resolution by up to 100×.
技术参数Ratio mode is used to normalize the signal to an externally applied analog voltage. It is useful to eliminate the effect of source intensity fluctuations.
技术参数Transfer function measurements can be easily made from the front panel by a programmable scan of up to 11 frequencies. Setups and offsets are recalled at each frequency in the scan.
技术参数Analog Inputs and Outputs
技术参数The two displays each have a user-defined output for measuring X, Y, R, R(dBm), Θ, and X-noise or Y-noise . Two user-programmable DACs provide -10.5 V to +10.5 V outputs with 1 mV resolution. These outputs may be set from the front panel or via the c

FAQ