UGAPM
UGAPM Series Gas Analyzers The UGAPM Series Process Monitoring Systems are modern mass spectrometers designed for the analysis of process gases. They operate from 20 Torr to 1 m...
广西科米瑞实验仪器设备有限公司提供 Stanford Research Systems UGAPM 产品资料、选型咨询、供货报价和售后服务支持,价格面议。
← 返回产品列表
UGAPM Series Gas Analyzers The UGAPM Series Process Monitoring Systems are modern mass spectrometers designed for the analysis of process gases. They operate from 20 Torr to 1 mTorr. The inlet continuously samples gases at low flow rates (about 5x10 -5 mbar L/sec) making the instrument ideal for on-line analysis . UGASoft Download UGA Tech Support RGA Basics UGA Comparison Meet a Customer 3D Step File QMS Series Gas Analyzers PPR Series Gas Analyzers UGA Series Gas Analyzer RGA100 Series Gas Analyzers RGA120 Series Gas Analyzers QMS Gas Analyzers PPR Gas Analyzers UGA Gas Analyzer RGA100 Series Gas Analyzers RGA120 Series Gas Analyzers UGAPM Series Process Monitoring Systems UGAPM Series — Process Monitoring Systems UGAPM applications include CVD/PECVD/RIE/LPCVD/MOCVD, vacuum coating/ plasma etching, evaporation, sputter deposition, vacuum heat treatment, target burn-in, leak detection/ virtual leaks/ desorption, contamination studies, small volume analysis (0.1 mL range), etc. These analyzers are also simple to operate and maintain. All the components can be controlled from the front-panel or a remote computer. In UGAPM systems, a SS capillary of 1/16” or 1/8” OD is used to accommodate mid-vacuum sampling . With this configuration, there is almost zero dead volume between the process chamber and the analyzer. Principle of operation The UGAPM system uses a single stage capillary pressure reducing inlet to sample gases from 1 mTorr to 20 Torr. After the pressure is reduced to around 10 -6 Torr , the gas stream is sent to a mass spectrometer (residual gas analyzer—RGA) which measures the concentration of each mass of interest. The UGAPM Windows software provides a graphical user interface for complex graphing and data analysis. The software also allows remote control of the system's valves, heaters and pumps. Multi-capillary inlet An optional multiple inlet valve is available with two possible configurations. One is the multichannel configuration, which may be applied for one specific sample pressure at various places. The other is the multi-range configuration, which may be applied for various ranges of the sample pressure. The UGAPM system can be controlled from the front-panel or from a computer. A choice of manual or auto-control of all system components is provided. Data is measured and displayed using the UGAPM software. The intuitive user interface allows measurements to be made quickly and easily. Data is captured and displayed in real-time, or scheduled for acquisition at a specified time. Features include analog and histogram scan modes, pressure vs. time plots, leak detection, gas library, and on-line help . RGA parameters can also be controlled and monitored through a high-level ASCII command et. Standard RS-232 and Ethernet interfaces are used as the data link to your PC. The UGAPM Analyzers offer the best value of any system currently available. They provide more performance, better features, and are priced well below the competition. UGAPM Specifications Stainless steel capillary, two extra 2-3/4" CF ports 10 -4 to 10 -5 Torr-L/sec at application pressures selectable from 1 X 10 -3 mbar to 15 mbar Faraday cup and electron multiplier 120, 220 or 320 atomic mass units (amu) Better than 0.5 amu at 10 % of peak height <10 ppm with Faraday cup detector, <1 ppm with electron multiplier 10 -4 mbar for FC, 10 -6 mbar for CDEM 1/16" or 1/8" Swagelok fitting 1/4" Tygon tube adapter Ethernet or RS-232C, DB9 connector 3 pin grounded cable Windows application. Controls UGAPM system including RGA. Hybrid turbomolecular/drag pump, 81 liter/s. Ultimate pressure 2 x 10 -9 mbar. Diaphragm pump with ultimate pressure less than 7 mbar. Protection class IP44 Viton ® , buna-N, and nitrile butyl rubber, copper gasket
请填写必填信息,我们将在工作日尽快回复。
| 技术参数 | UGAPM applications include CVD/PECVD/RIE/LPCVD/MOCVD, vacuum coating/ plasma etching, evaporation, sputter deposition, vacuum heat treatment, target burn-in, leak detection/ virtual leaks/ desorption, contamination studies, small volume analysis (0.1 |
|---|---|
| 技术参数 | The UGAPM Windows software provides a graphical user interface for complex graphing and data analysis. The software also allows remote control of the system's valves, heaters and pumps. |
| 技术参数 | An optional multiple inlet valve is available with two possible configurations. One is the multichannel configuration, which may be applied for one specific sample pressure at various places. The other is the multi-range configuration, which may be a |
| 技术参数 | Data is measured and displayed using the UGAPM software. The intuitive user interface allows measurements to be made quickly and easily. Data is captured and displayed in real-time, or scheduled for acquisition at a specified time. |
| 技术参数 | RGA parameters can also be controlled and monitored through a high-level ASCII command et. Standard RS-232 and Ethernet interfaces are used as the data link to your PC. |
| 技术参数 | The UGAPM Analyzers offer the best value of any system currently available. They provide more performance, better features, and are priced well below the competition. |