中文English
科米瑞
首页联系我们
  1. 首页
  2. 产品中心
  3. 产品详情
科米瑞

© Copyright 科米瑞 2026

产品中心产品目录应用领域知识中心常见问题联系我们隐私政策桂ICP备2020008265号-5
广西科米瑞实验仪器设备有限公司13422079856122816084@qq.com
分析检测仪器生命科学仪器显微成像与光学样品前处理温控加热与制冷真空泵阀与流体科米瑞仪器应用领域实验室仪器选型

BI-200SM – Research Grade Light Scattering Goniometer

BI-200SM – Research Grade Light Scattering Goniometer

Brookhaven Instruments’ scientists have extensive experience in the development of instruments and methods for light scattering. This experience has been incorporated into the B...

品牌: Brookhaven Instruments价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司提供 Brookhaven Instruments BI-200SM – Research Grade Light Scattering Goniometer 产品资料、选型咨询、供货报价和售后服务支持,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
BI-200SM – Research Grade Light Scattering Goniometer
说明规格FAQ

说明

Brookhaven Instruments’ scientists have extensive experience in the development of instruments and methods for light scattering. This experience has been incorporated into the BI-200SM Research Goniometer to make it the finest instrument available for research applications of light scattering.

With a Brookhaven Instruments BI-200SM Research Goniometer System, this rich field of exploration is open to you for studies of both Static Light Scattering ( SLS ) and Dynamic Light Scattering ( DLS ).

The Bl-200SM Research Goniometer System provides access to all of these studies with an automatic, modular, and versatile system. It is a precision instrument designed for exacting scattering measurements. Based on a special turntable with precision ball bearings and a stepping motor, the Bl-200SM’s modern design and quality construction guarantee precise measurements due to the wobble-free movement of the detector. It is field-proven in hundreds of laboratories. It is ideal for macro-molecular studies and submicron particle sizing.

By taking advantage of the multiple inputs available on the TurboCorr TM correlator a new capability of the BI-200SM system is created. By adding an optical signal splitter to the beam of scattered light and a second detector it is possible to eliminate the effects of very high-speed interference from the detector(s). This Cross-Correlation System provides remarkably clean information as seen in the article we have presented.

The BI-200SM Research Goniometer modularity simplifies system expansion. Featuring a standard optical rail, the BI-200SM can be used with neutral density filters, a polarizer, an analyzer, and a reference detector. Special sample requirements can often be met by changing the cell holder design or size.

规格

Beam Focus and SteeringIncludes mounts, adjustments, and apertures
Turntable200 mm O.D. turntable, worm gear, and ball bearings; manual or automatic selection of angles in 0.01° steps; precision machine base with mounting holes; positioning table with micrometer adjustments (power supply and controller for stepping motor is
Specimen Cell AssemblyIncluding thermal enclosure, centering adjustments, separate plumbing for temperature control and index matching liquids, round cell holders, square cell holder and alignment cell
Index Matching VatWith optically flat and specially polished entrance window, precision machined and annealed to minimize stray light
Periscopic Beam StopLocated inside vat to prevent flare from exit window; provided with coupling for use with optional, zero-angle reference detector
Main Detector OpticsEntrance aperture 3 mm Coated, adjustable achromat for focusing scattered light onto 200 micron slit; slit position adjustable Reflex mirror and high-quality eye-piece for viewing scattering region through slit Filter turret with 637, 532, 633, 514 a
BI-200SMPtAllows direct measurement of temperature in the index-matching liquid near the sample cell.
BI-FCFiltration system for cleaning index matching liquid
BI-PAPolarization Analyzer, Glan-Thompson prism, 5×10 -6 extinction
BI-SFSThe BI-SFS sample filtration system provides a fast and convenient way to clean your light-scattering samples, a necessity for samples smaller than 20 nm. Utilizing Teflon tubing and nonreactive components, the BI-SFS is compatible with most sample f
BI-RC25Nominal 25 mm O.D. Round Quartz Cell, dual Teflon tops, mounting ring
BI-RC27Nominal 27.5 mm O.D. Dilution Vials, a package of 100 with HDPE screw caps
BI-SVCSmall-volume cell for precious samples
BI-SVCHSmall volume round cell holder and universal SVC sleeve
BI-SCHSquare cell holder. Use with BI-SCG and BI-SCQ. (Only one is required when using square cells)
BI-SCGSquare glass, 12.5×12.5x45mm, PTFE stopper: Requires BI-SCH

FAQ

相关产品

NanoBrook Series

NanoBrook Series

NanoBrook Series

BI-DCP – Disc Centrifuge Photosedimentometer

BI-DCP – Disc Centrifuge Photosedimentometer

BI-DCP – Disc Centrifuge Photosedimentometer

BI-MwA – Molecular Weight Analyzer

BI-MwA – Molecular Weight Analyzer

BI-MwA – Molecular Weight Analyzer

BI-DNDC – Refractive Index Increment Analyzer

BI-DNDC – Refractive Index Increment Analyzer

BI-DNDC – Refractive Index Increment Analyzer

BI-RIVS – Refractive Index

BI-RIVS – Refractive Index

BI-RIVS – Refractive Index

BI-870 Dielectric Constant Meter

BI-870 Dielectric Constant Meter

BI-870 Dielectric Constant Meter

提交需求