中文English
科米瑞
首页联系我们
  1. 首页
  2. 产品中心
  3. 产品详情
科米瑞

© Copyright 科米瑞 2026

产品中心产品目录应用领域知识中心常见问题联系我们隐私政策桂ICP备2020008265号-5
广西科米瑞实验仪器设备有限公司13422079856122816084@qq.com
分析检测仪器生命科学仪器显微成像与光学样品前处理温控加热与制冷真空泵阀与流体科米瑞仪器应用领域实验室仪器选型

Automatic Cold Filter Plugging Point Analyzer with Touch Screen

Automatic Cold Filter Plugging Point Analyzer with Touch Screen

Determines the highest temperature at which a given volume of diesel, biodiesel or heating fuel fails to pass through a standardized wire mesh filtration device in a specified t...

品牌: Koehler Instrument价格: 面议服务区域: 全国

广西科米瑞实验仪器设备有限公司生产销售 Koehler Instrument Automatic Cold Filter Plugging Point Analyzer with Touch Screen,可提供产品参数、报价和售后服务咨询,价格面议。

立即询价查看更多详情咨询该型号
← 返回产品列表
Automatic Cold Filter Plugging Point Analyzer with Touch Screen

Determines the highest temperature at which a given volume of diesel, biodiesel or heating fuel fails to pass through a standardized wire mesh filtration device in a specified time when cooled under specified conditions. The Cold Filter Plugging Point (CFPP) of a fuel is suitable for estimating the lowest temperature at which a fuel will give trouble-free flow in certain fuel systems. Conforms to ASTM D6371 and related specifications Stand alone system with Integrated Touch Screen Panel PC Direct Cooling system eliminates the need for solvent cooling baths One-stage cooling system provides temperatures as low as -45°C and a two-stage cooling system down to -80°C Internal vacuum generation system Safety Features: Audible alarm and displayed messages (at the end of the analysis and in case of errors and/or malfunctions) Pressure controller for 1st and 2nd stage motor compressor Thermostat for 2nd stage activation Thermo-switch for each cooling / heating jacket Motor compressors equipped with internal overload devices The cold filter plugging point detection system provides automated sample testing with the accuracy and repeatability in accordance with ASTM D6371 and related international test methods. The sample is cooled according to the pre-selected temperature profile. A 20 mBar vacuum is applied to the sample at specific intervals across a 45 micron mesh filter into the aspiration glass cell assembly. If it takes more than 60 seconds for the sample to reach the upper barrier detector or more than 60 seconds to return below the detector upon release, then the test is complete and the cold filter plugging point has been reached. s complete and the cold filter plugging point has been reached. Integrated Panel PC and Software Package – The KLA Series of analyzers are complete standalone systems featuring an integrated panel PC with an advanced software package. The 12” TFT/LCD touch screen display has a resolution of 1024x768 with a 16.2 M color scheme. All analytical parameters are graphed and displayed in real time as well as recorded in Microsoft® Excel compatible file format. The software monitors the operation and performance of all the analyzer components for proper data measurement, including the solenoid valves, cooling system, pressure sensors, and the Platinum resistance PT100 Class A temperature probe . Cooling System – For various user applications, the automated cold filter plugging point system comes standard with cooling for temperatures as low as -95°C. The direct cooling system features integrated gas CFC free motors compressors thus eliminating the need for a solvent cooling bath. The direct system is capable of rapid cooling, approaching -80°C bath temperatures in approximately 15 minutes, and utilizes less electricity than standard cooling systems. The rapid cooling feature combined with a consistent cooling profile system provides repeatable results with high test reproducibility. Vacuum System – The automated cold filter plugging point analyzer includes an internal vacuum generator. The internal vacuum generator provides a smaller footprint for the complete CFPP system and consists of a 350 mBar micro-pump and an electronic pressure/vacuum regulator composed of a proportional valve, pressure/vacuum control sensor, regulator for reference vacuum generation at 20 mBar and a vacuum stabilizer. Multiple Configuration System –These automated sample cooling and physical property measurement systems can be configured with one, two, three, four and six test positions with one of five possible analytical heads at each position: cloud point, pour point, cloud & pour point, cold filter plugging point and freezing point. Standard and customized multiple configuration systems are readily available. Calibrated Aspiration Pipette complete with Filter Kit for CFPP Cord Cable without plug

相关产品

Vapor Pressure of Crude Oil & Petroleum Products

Vapor Pressure of Crude Oil & Petroleum Products

Vapor Pressure of Crude Oil & Petroleum Products

Dissolution Test Apparatus

Dissolution Test Apparatus

Dissolution Test Apparatus

Tap Density Tester

Tap Density Tester

Tap Density Tester

Tablet Disintegration Tester

Tablet Disintegration Tester

Tablet Disintegration Tester

Hardness Tester

Hardness Tester

Hardness Tester

Friability Tester

Friability Tester

提交需求

请填写必填信息,我们将在工作日尽快回复。

Friability Tester