LKV5000 Refrigerated Kinematic Viscosity Bath with Optical Flow Detection System
LKV5000 Refrigerated Kinematic Viscosity Bath with Optical Flow Detection System
Kinematic viscosity is of primary importance in the design and selection of a wide range of petroleum products. Calibrated capillary viscometers are used to measure flow under g...
广西科米瑞实验仪器设备有限公司生产销售 Koehler Instrument LKV5000 Refrigerated Kinematic Viscosity Bath with Optical Flow Detection System,可提供产品参数、报价和售后服务咨询,价格面议。
← 返回产品列表
Kinematic viscosity is of primary importance in the design and selection of a wide range of petroleum products. Calibrated capillary viscometers are used to measure flow under gravity or vacuum at precisely controlled temperatures. Complete instrument and data acquisition system exclusively designed for conducting ASTM D445, IP 71 and related test methods Optical sensor detection system accurately measures sample flow and automatically calculates kinematic viscosity results Powerful software system for PC platforms operating in Windows® XP, Vista, 7 and 8 environments Automatic calculation and display of results in viscosity units or seconds Accommodates Ubbelohde, Cannon®- Fenske, and Cannon®- Fenske Opaque Reverse Flow viscometers High accuracy temperature control with dual digital displays show set point and actual bath temperature with selectable scale (°C or °F) Stand alone feature provides for automated testing without an external PC Improved design with enhanced performance and safety features Software exports test data with graphs and test parameters direct to CSV file format for use with LIMS or any other spreadsheet program Integrated digital timing for easy measurement of sample efflux times The LKV5000 operates at temperatures from ambient to -30 °C (-22 °F) or ambient to -70 °C (-94 °C), model dependent, exceeding ASTM temperature control accuracy and uniformity requirements throughout the operating range. Air-cooled hermetic compressors provide efficient operation with the use of CFC-free refrigerants. The insulated steel cabinet has an attractive polyester-epoxy finish and is mounted on adjustable leveling feet. Chemical resistant working (top) surface has four round ports for 2" (51mm) viscometer holders and one port for a thermometer holder. The front viewing window provides clear, distortion-free visibility. The microprocessor controller incorporates circuitry that interrupts power to the heater in the event of an over-temperature condition or disconnection of the primary probe. A redundant adjustable controller and sensor probe provide added over-temperature protection, and an integrated low liquid level sensor cuts power to the heaters if the bath liquid is not filled to the proper level or falls below during operation. Both over-temperature and low liquid level circuits will latch and prevent further operation of the bath until the fault is removed. Port Cover, Delrin® (4) Thermometer Holder Conforms to the specifications of: ASTM D445, D2170, D6074, D6158; IP 71, 319; ISO 3104; DIN 51550; FTM 791-305; NF T 60-100 Testing Capacity: Four (4) glass capillary viscometers
提交需求
请填写必填信息,我们将在工作日尽快回复。
-1000x1000.png)